Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
International Journal of Laboratory Medicine ; (12): 2214-2215,2217, 2015.
Article in Chinese | WPRIM | ID: wpr-602321

ABSTRACT

Objective To investigate diagnostic value of GP73 in alcoholic disease .Methods GP73 was measured by ELISA in 44 alcoholic fatty liver ,43 alcoholic hepatitis ,32 alcoholic cirrhosis ,67 non‐alcoholic fatty liver patients and 120 healthy control per‐sons .Meanwhile ALT ,AST ,ALP ,GGT ,Alb ,TBil ,AFP were measured .Results GP73 of alcoholic fatty liver ,alcoholic hepatitis , alcoholic cirrhosis ,non‐alcoholic fatty liver patients and healthy control group were (84 .22 ± 26 .22) ,(157 .98 ± 39 .71) ,(201 .23 ± 61 .14) ,(62 ± 14 .02) ,(47 .08 ± 22 .75)ng/mL respectively .The GP73 differences between patients and healthy control group had statistical significance(P<0 .05) .Before and after therapy of alcoholic hepatitis and alcoholic cirrhosis patients had statistical signif‐icance(P<0 .05) .Sensitivity of diagnostic value of GP73 in ALD was 71 .4% and specification was 95 .2% .Conclusion Serum GP73 elevates in types of alcoholic liver disease and show significant diagnostic value .Decrease of GP73 could be applied to assess treatment of alcoholic hepatitis and alcoholic cirrhosis .

2.
International Journal of Laboratory Medicine ; (12): 669-670,712, 2015.
Article in Chinese | WPRIM | ID: wpr-600589

ABSTRACT

Objective To verify the performance of the ABI ViiA 7 Taqman HBV-DNA detecting system for confirming its sta-bility,accuracy and reliability.Methods According to the evaluation protocols of Clinical and Laboratory Standards Institute (CLSI),the performance of ABI ViiA 7 Taqman HBV-DNA detecting system was assessed in the aspects of precision,accuracy,lin-earity and comparability;the quantitative detection limit validation experiments was performed by diluting specimen until quantita-tive detection limit is lower than the lower limit of detection,and the detection results were compared with the quality target re-quirements and the analysis capability declared by manufacturers.Results The CV in within-run precision of this detection system was 1.485%,1.990% and 0.932% respectively;the total CV was 1.876%,3.361% and 1.891%,respectively;the maximum devia-tion of accuracy was -6.8%;the linear correlation coefficient was 0.998 3;the regression equation was Y =0.974 8X +0.050 7. The linear range was 1.00E2 - 2.00E8;the quantitative detection limit was 100 IU/mL;the comparability of ABIViiA7 and ABI7500:P =0.115,r2 =0.994,the linear regression equation was Y =0.987 2X +0.051 7.Conclusion The ABI ViiA 7 Taqman HBV-DNA detection system has excellent precision,accuracy,sensitivity and linearity and has a good correlation with ABI7500, which can be used for the detection of clinical specimens.

3.
International Journal of Laboratory Medicine ; (12): 2818-2819,2822, 2014.
Article in Chinese | WPRIM | ID: wpr-600280

ABSTRACT

Objective To discuss the setting problem of control limit for quality control chart during the statistical quality con-trol procedure of clinical laboratory quantitative measurement.Methods The normality test of the monthly quality control data for 3 items of albumin (ALB),alanine aminotransferase (ALT)and creatinine (Cr)was performed by using the SPSS 14.0 statistical software and which was compared with the cumulated data.Results Among 30 groups of data,the normality test was inconformity in 18 groups,among 30 groups of mean t test,the differences in 20 groups showed statistical significance(P <0.05).Therefore,the calculated means and standard deviation(SD)in short term could not be directly set as the control limit of the quality control chart. Conclusion Setting the control limit of internal quality control in clinical laboratory quantitative measurement should be according to the guidance of C24-A3 document in CLSI.The SD estimated value obtained from large amount stable quality control data or the 6-month cumulative values is recommended to be used as SD of the new batch number,which should be regularly assessed.

4.
West China Journal of Stomatology ; (6): 434-441, 2011.
Article in Chinese | WPRIM | ID: wpr-235026

ABSTRACT

<p><b>OBJECTIVE</b>To research the effects of incorporating tetrapod-like zinc oxide whisker (T-ZnOw) of different proportions on the antibacterial activity of different kinds of soft denture liners.</p><p><b>METHODS</b>The minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC) of T-ZnOw against Saccharomyces albicans (S. albicans) were examined by the broth dilution test. Add T-ZnOw 0%, 1%, 2%, 3% to Silagum soft denture liners and soft denture liners respectively. The antimicrobial rate of S. albicans was determined by the membrane covering method.</p><p><b>RESULTS</b>The MIC of T-ZnOw against S. albicans was 78 microg mL(-1) and the MBC was 156 microg mL(-1). Comparing 1%, 2%, 3% T-ZnOw group with control group, the results showed significant difference (P<0.05). And as the T-ZnOw antibacterial agent added ratio increased, antibacterial increased significantly.</p><p><b>CONCLUSION</b>The soft denture liners incorporating with 1%, 2%, 3% of T-ZnOw can improve antibacterial activity. Following the increased proportions of T-ZnOw, antibacterial rate was significantly increasing.</p>


Subject(s)
Animals , Anti-Bacterial Agents , Denture Liners , Microbial Sensitivity Tests , Vibrissae , Zinc Oxide
5.
Journal of Biomedical Engineering ; (6): 605-607, 2003.
Article in Chinese | WPRIM | ID: wpr-312917

ABSTRACT

To evaluate the effect of impeller design on pump hemolysis, five impellers with different number of vanes or different vane angles were manufactured and tested in one pump for hemolysis comparison. The impellers are made to have the same dimension and same logarithmic spiral vane from which coincide with the stream surfaces in the pump, according to the analytical and three-dimensional design method developed by the authors. Consequently, an impeller with 6 vanes and 30 degrees vane angle has the lowest hemolysis index. This result agrees with the theoretical analyses of other investigators searching optimal number of vanes and vane angle to achieve the highest efficiency of the pump.


Subject(s)
Humans , Heart-Assist Devices , Hemolysis , In Vitro Techniques , Prosthesis Design
6.
Journal of Practical Radiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-536379

ABSTRACT

Objective To discuss real time three-dimensional reconstruction techniques of spiral CT in the detection of tracheoesophageal groove lymph node metastasis and its diagnostic value.Methods Spiral CT RT3D reconstruction of the supraclaviculrar region were applied to 45 patients with scanning and post-processing on the workstation.Mediastinum,color in chest,clip planes 3D images were obtained by adjusting the CT value threshold and encoding pseudo color techniques.Results RT3D images can correctly reveal the macroscopic morphology of lymphatic metastasis and it's pressure to the trachea and carotid artery.There were significant differennces of visualization capabilities of radiological signs among different 3D techniques.Conclusion With the utilization of multiple methods,RT3D reconstruction can play an important role in detecting tracheoesophageal groove lymph node metastasis of esophageal cancer.It is an important complement to the axial CT images and the basis of clinical treatment.

7.
Chinese Journal of General Surgery ; (12)1993.
Article in Chinese | WPRIM | ID: wpr-527300

ABSTRACT

Objective To evaluate one-stage procedure for the treatment of neonatal intermediate and high imperforated anus. Methods Clinical data of 21 neonates with intermediate or high imperforated anus undergoing one-stage surgical procedure were summarized. Results Postoperative complication included mucous overlap and soiling in 1 case, and occasional soiling in 2 cases. No postoperative constipation developed in any case. Conclusions Neonatal one-stage procedure avoids short comings often seen in staged procedures and needs no colostomy, promoting hyperplasia and prolongs sphincter during early stage, preventing secondary megacolon.

SELECTION OF CITATIONS
SEARCH DETAIL